Engineering Library - Product Technical Support - Speak with an Engineer

Full Range Flows by Pipe Size

GAGE
RANGE
(in W.C.)

MEDIA @ 70* F

FULL FLOWS BY PIPE SIZE (APPROXIMATE)

1"

1-1/4"

1-1/2"

2"

2-1/2

3"

4"

5"

8"

10"

2

WATER (GPM)
AIR  @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

4.8
19.0
50.0

8.3
33.0
90.5

11.5
42.0
120.0

20.5
65.O
210.0

30
113
325

49
183
510

86
330
920

205
760
2050

350
1340
3600

560
2130
6000

5

WATER (GPM)
AIR @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

7.7
30.0
83.0

14.0
51.0
142.0

18.0
66.0
190.0

34.0
118.0
340.0

47
178
610

78
289
820

138
510
1600

320
1200
3300

560
2150
5700

890
3400
10000

10

WATER (GPM)
AIR @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

11.0
41.0
120.0

19.0
72.0
205.0

25.5
93.0
275.0

45.5
163.0
470.0

67
250
740

110
410
1100

195
725
2000

450
1690
4600

800
3040
8100

1260
4860
15000

25

WATER (GPM)
AIR @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

18.0
63.0
185.0

32.0
112.0
325.0

40.5
155.0
430.0

72.0
255.0
760.0

108
390
1200

173
640
1800

310
1130
3300

720
2630
7200

1250
4860
13000

2000
7700
22000

50

WATER (GPM)
AIR @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

25.0
90.0
260.0

44.0
161.0
460.0

57.5
205.0
620.0

100.0
360.0
1050.0

152
560
1700

247
900
2600

435
1600
4600

1000
3700
10000

1800
6400
18500

 

100

WATER (GPM)
AIR @ 14.7 PSIA (SCFM)
AIR @ 100 PSIG (SCFM)

36.5
135.0
370.0

62.O
230.0
660.0

82.0
300.0
870.0

142.0
505.0
1500.0

220
800
2300

350
1290
3600

620
2290
6500

1500
5000
15000

 

 


Pressure Correction Factors
Regulator
Inlet  Pressure
Pressure
Factor
1 psig 1.05
2 psig 1.11
3 psig 1.18
4 psig 1.25
5 psig 1.32
6 psig 1.39
7 psig 1.45
8 psig 1.52
9 psig 1.59
10 psig 1.66
11 psig 1.72
12 psig 1.81
13 psig 1.86
14 psig 1.93
15 psig 2.0

To set desired input change BTU input on boiler to cu. ft. by subtracting the last 3 zeros. If gas supply pressure is over 1 psig take the corresponding pressure factor from the above chart and divide it into the input. This is the actual input required at the supply pressure.

EXAMPLE:

The boiler input is equal to 2,500,000 BTU minus 3 zeros = 2,500 cu. ft. input. The gas supply pressure is 2 psig = 1. 11 correction factor. 2,500 ? 1.11 = 2,250. 2,250 = 16 seconds on 10 cu. ft. dial.

Download in PDF format for printing

This documents require Adobe's free Acrobat Reader to view.

Home - About Us - Products & Services - TechCenter - Online Store - Get Literature - Repair & Rebuilt Controls
Find it Fast!
- Mfgr's Parts Lists - Contact Us - Terms

Copyright © 2005 CAPP/USA All Rights Reserved.

DISCLAIMER: THIS WEBSITE IS NOT SANCTIONED OR APPROVED BY ANY OF THE MANUFACTURER'S LISTED WITHIN. CAPP/USA IS NOT AFFILIATED WITH ANY OF THE MANUFACTURER'S IN THIS SITE AND RECOGNIZES THAT ALL OF THE MANUFACTURER'S ARE REGISTERED TRADEMARKS.

Site design and hosting by Voicenet