TARGET SETPOINT |
SEE " SETPOINT, TARGET" |
TDC |
TDC-2000 & TDC-3000 ARE COMPLETE COMPUTER-BASED PROCESS CONTROL SYSTEMS DEVELOPED BY HONEYWELL THAT PROVIDE THE MONITORING, CONTROLLING, & AUTOMATION OF A N INDUSTRIAL PLANT'S PROCESS CONTROL LOOP(s)/SYSTEMS |
TE |
STANDS FOR TOTALLY ENCLOSED |
TEAO |
STANDS FOR TOTALLY ENCLOSED, AIR OVER |
TEFC |
STANDS FOR TOTALLY ENCLOSED, FAN COOLED |
TEFLON |
MANUFACTURED BY DuPONT, TEFLON IS A FLUOROCARBON-BASED POLYMER THAT IS USED FOR THE INSULATION OF WIRES. |
TEMPCO |
STANDS FOR "TEMPERATURE COEFFICIENT". |
TENV |
STANDS FOR TOTALLY ENCLOSED, NON-VENTILATED |
THERMOCOUPLE |
A TEMPERATURE SENSING DEVICE THAT IS CONSTRUCTED OF TWO DISSIMILAR METALS WHERIN A MEASURABLE & PREDICTABLE VOLTAGE IS GENERATED CORRESPONDING TO TEMPERATURE; SEE OUR WIDE-VARIETY OF THERMOCOUPLES STARTING ON Pg.____. |
THERMOCOUPLE BREAK PROTECTION |
A FAIL-SAFE OPERATION THAT ASSURES DESIRED OUTPUT UPON AN OPEN THERMOCOUPLE CONDITION |
THERMOCOUPLE DOWNSCALE BURNOUT |
THE JUMPER POSITION THAT DETERMINES WHETHER, WHEN A THERMOCOUPLE FAILS, ITS OUTPUT IS REPLACED BY A MILLIVOLTAGE WHICH WILL MATCH THE THERMOCOUPLE'S MINIMUM VALUE |
THERMOCOUPLE UPSCALE BURNOUT |
THE JUMPER POSITION THAT DETERMINES WHETHER, WHEN A THERMOCOUPLE FAILS, ITS OUTPUT IS REPLACED BY A MILLIVOLTAGE WHICH WILL MATCH THE THERMOCOUPLE'S MAXIMUM VALUE |
THERMOSTAT |
MEASURES AMBIENT TEMPERATURE AND CONTROLS OTHER DEVICES IN AN HVAC SYSTEM. THERMOSTATS COME IN A WIDE VARIETY AND ARE GENERALLY EITHER ELECTRIC-DELIVERED OR PNEUMATIC |
THREE MODE CONTROL |
SEE "CONTROL ACTION, PID" |
THROTTLING RANGE (CONTROLS) |
THE CHANGE IN ANY VARIABLE SUCH AS TEMPERATURE, PRESSURE, ETC. REQUIRED TO CAUSE A CONTROLLER'S OUTPUT TO VARY A PRE-DEFINED RANGE. |
THROTTLING RANGE (SYSTEM) |
THE AMOUNT OF CHANGE OF ANY VARIABLE SUCH AS TEMPERATURE, PRESSURE, ECT. NECESSARY FOR THE CONTROLLER TO DRIVE THE ACTUATOR(S) THROUGH THEIR COMPLETE STROKE(S) |
TIME PROPORTIONING CONTROL |
A CONTROL ALGORITHM THAT EXPRESSES OUTPUT POWER ( 0-100% ) AS A FUNCTION OF PERCENT "ON" VS. PERCENT "OFF" WITHIN A PRESET CYCLE TIME |
TIME PROPORTIONING OUTPUT |
A CONTROLLER OUTPUT THAT IS ASSIGNED BY SOFTWARE TO FACILITATE TIME PROPORTIONAL CONTROL (GENERALLY A RELAY, SSR, OR SSR DRIVE OUTPUT) |
TORQUE |
TYPICALLY PRODUCES ROTATION OR TWISTING SUCH AS IN MOTORS |
TOTAL PRESSURE |
TOTAL PRESSURE IS MEASURED BY THE SUM OF STATIC AND VELOCITY PRESSURE |
TRACKING |
A PROCESS CONTROLLER FUNCTION THAT DEFINES WHETHER THE LOCAL SETPOINT WILL TRACK THE REMOTE SETPOINT; WHEN THE CONTROLLER IS TRANSFERRED TO A LOCAL SETPOINT, THAT LOCAL SETPOINT VALUE WILL MATCH THE REMOTE PROCESS VALUE WHEN THE TRANSFER OCCURS |
TRANSDUCER |
A DEVICE THAT CONVERTS ONE SIGNAL TO ANOTHER; EXAMPLE: CONVERTING A 4 TO 20 mA SIGNAL TO A 3 TO 15 PSI SIGNAL, AND VICE-VERSA |
TRANSMITTER (2-WIRE) |
USED TO TRANSMIT DATA VIA A TWO WIRE CURRENT LOOP; A 2-WIRE TRANSMITTER IS LOOP POWERED. SEE OUR LARGE TRANSMITTER SECTIONS FOR HONEYWELL, FOXBORO, ROSEMOUNT, & DWYER TRANSMITTERS |
TRANSMITTER (4-WIRE) |
USED TO TRANSMIT DATA VIA A CURRENT LOOP OR A DC VOLTAGE; A 4-WIRE TRANSMITTER USES 2 WIRES FOR DATA & 2 WIRES FOR POWER; SEE OUR LARGE TRANSMITTER SECTIONS FOR HONEYWELL, FOXBORO, ROSEMOUNT, & DWYER TRANSMITTERS |
TRIAC |
A SOLID STATE SWITCHING DEVICE USED TO SWITCH ALTERNATING CURRENT SIGNALS ON & OFF; TRIAC CIRCUITS ARE ALSO REFERRED TO AS SOLID STATE RELAYS OR SSR's |
TRIP POINT |
THE VALUE THAT DETERMINES WHEN THAT SET OF PID VALUES BECOMES ACTIVE |
TRIPLE POINT |
TERM USED TO DESCRIBE SOLID, LIQUID, AND VAPOR PHASES WHICH ARE ALL IN EQUALIBRIUM AT THE SAME TIME SO THAT THERE IS A "FIXED-POINT" TEMPERATURE OF THE MATERIAL THAT IS BEING MEASURED. |
TRUE RMS |
OFTEN USED IN DETERINING THE POWER OF A SIGNAL BY A MULTIMETER, IT STANDS FOR THE TRUE ROOT-MEAN-SQUARE VALUE OF AN AC OR AC + DC SIGNAL. |
|
UDC |
STANDS FOR "UNIVERSAL DIGITAL CONTROLLER", WHICH IS A PROCESS TEMPERATURE CONTROLLER MANUFACTURED BY HONEYWELL. UDC'S COME IN SERIES 2000, 3000, 5000, 6000, & 9000 |
UL |
STANDS FOR UNDERWRITERS LABORATORIES, INC., ESTABLISHES STANDARDS FOR PRODUCTS |
ULTRAVIOLET |
APPROXIMATELY 380 NANOMETERS BELOW BLUE LIGHT, ULTRAVIOLET OR "UV" IS OFTEN DETECTED AS A PART OF THE FLAME IN BOILERS, BURNERS, OVENS, KILNS, AND INCINERATORS. |
UPSCALE BURNOUT |
SEE "THERMOCOUPLE UPSCALE BURNOUT" |
UV |
STANDS FOR ULTRA-VIOLET |