N.C. |
SEE "NORMALLY CLOSED" |
N.O. |
SEE "NORMALLY OPEN" |
NBS |
STANDS FOR NATIONAL BUREAU OF STANDARDS |
NEC |
STANDS FOR NATIONAL ELECTRIC CODES |
NEMA |
STANDS FOR NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION |
NETWORK 8000 |
A DIRECT DIGITAL CONTROL (DDC) SYSTEM DEVELOPED BY BARBER-COLMAN CO. (SIEBE CO.) THAT PROVIDES COMPLETE HVAC-BUILDING AUTOMATION |
NFPA |
STANDS FOR THE NATIONAL FIRE PROTECTION ASSOCIATION |
NIGHT SETBACK |
A CONDITION GENERALLY ASSOCIATED WITH THERMOSTATS, THAT IS WHEN THE SETPOINT OF THE THERMOSTAT IS SET/SHIFTED TO A LOWER TEMPERATURE DURING UNOCCUPIED HOURS, ESPECIALLY DURING THE HEATING SEASON |
NIGHT SETUP |
GENERALLY ASSOCIATED WITH THERMOSTATS, WHEN THE SETPOINT IS SET/SHIFTED TO A HIGHER TEMPERATURE DURING UNOCCUPIED HOURS, ESPECIALLY DURING THE COOLING SEASON |
NIST |
STANDS FOR NATIONAL INSTITUTE FOR STANDARDS AND TECHNOLOGY. |
NOISE |
AN UNWANTED COMPONENT OF A SIGNAL OR VARIABLE |
NORMALLY CLOSED |
A TERM/CONDITION THAT APPLIES TO A CONTROLLED DEVICE WHICH CLOSES WHEN EITHER A POWER FAILURE OCURRS, OR WHEN CONTROL PRESSURE IS REMOVED |
NORMALLY OPEN |
A TERM/CONDITION THAT APPLIES TO A CONTROLLED DEVICE THAT IS OPEN WHEN ALL OPERATING FORCE IS LOST, SUCH AS IN A POWER FAILURE |
NPT |
STANDS FOR NATIONAL PIPE THREAD |
|
O.D. |
STANDS FOR OUSIDE DIAMETER |
OA |
STANDS FOR OUTDOOR AIR |
OCCUPIED MODE |
A CONTROL MODE THAT IS USED TO HEAT OR COOL BUILDINGS WHILE THEY ARE OCCUPIED |
OFFSET |
THE AMOUNT OF DIFFERENCE BETWEEN CONTROL POINT AND SETPOINT IN A PROPORTIONAL CONTROL SYSTEM |
OFFSET |
THE ADJUSTMENT TO THE ACTUAL INPUT TENMPERATURE AND TO THE TEMPERATURE VALUES THAT THE CONTROLLER USES FOR DISPLAY & CONTROL |
OHMETER |
USED TO MEASURE ELECTRICAL RESISTANCE |
ON/OFF CONTROL |
SEE "CONTROL, ON/OFF" |
OPEN LOOP |
A CONTROL SYSTEM WITH NO SENSORY FEEDBACK |
OSHA |
STANDS FOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION |
OUTPUT |
AN ACTION CAUSED IN RESPONSE TO THE DIFFERENCE BETWEEN SETPOINT AND PROCESS VARIABLE |
OUTPUT MODULES |
GENERALLY PLUG-IN DEVICES SUCH AS RELAYS THAT PROVIDE POWER HANDLING TO ENABLE PROCESS CONTROL; MODULES CAN BE EITHER BINARY (ON/OFF) OR ANALOG (CONTINUOUSLY VARIABLE) FOR CURRENT LOOP CONTROL |
OVERSHOOT |
THE CONDITION WHEN TEMPERATURE EXCEEDS SETPOINT DUE TO INITIAL POWER-UP OR PROCESS CHANGES |
OXIDIZING |
AN ATMOSPHERE THAT CONTAINS SIGNIFICANT AMOUNTS OF ACTIVE OXYGEN. |
|
P CONTROL |
STANDS FOR "PROPORTIONING" CONTROL |
PARAMETER |
ANY SPECIFIC CHARACTERISTIC OF A DEVICE/CONTROL |
PARITY |
ADDITION OF ALL THE BITS IN A WORD IS COMPARED TO THE PARITY BIT (EVEN OR ODD). IF THEY ARE BOTH THE SAME, THE DATA IS ACCEPTED, OTHERWISE IT IS REJECTED. |
PB |
STANDS FOR PROPORTIONAL BAND |
PCB |
STANDS FOR PRINTED CIRCUIT BOARD |
PD CONTROL |
STANDS FOR "PROPORTIONING CONTROL WITH RATE ACTION |
PEAK LOAD |
THE MAXIMUM ELECTRICAL LOAD OR THERMAL LOAD REACHED DURING A SPECIFIC PERIOD OF TIME |
PERCENT AUTHORITY |
GENERALLY COMMON WITH THE ADJUSTMENT OF RECEIVER CONTROLLERS WHICH DETERMINES THE EFFECT OF THE RESET SIGNAL OF THE SECONDARY TRANSMITTER AS A PERCENTAGE (%) OF THE SIGNAL OF THE PRIMARY TRANSMITTER |
PHENOLIC |
A RESIN BASED TYPE OF HARD RUGGED PLASTIC THAT IS USUALLY USED IN INSULATING. PHENOLIC IS THE SAME AS BAKELITE. |
PI CONTROL |
STANDS FOR "PROPORTIONING CONTROL WITH AUTO-RESET" |
PID CONTROL |
STANDS FOR "PROPORTIONING CONTROL WITH AUTO-RESET AND RATE" |
PLATINUM |
THE NOBLE METAL GENERALLY USED IN TYPES R & S THERMOCOUPLES |
PNEUMATIC CONTROLS |
CONTROLS THAT RUN ON LOW-PRESSURE COMPRESSED AIR |
PNEUMATIC FINISH POINT |
THE MAXIMUM AMOUNT OF PRESSURE (PSI) THAT WILL COMPLETELY COMPRESS AN ACTUATOR'S SPRING TO COMPLETE ITS STROKE. EXAMPLE: AN ACTUATOR WITH A SPRING RANGE OF 3 TO 8 PSI; "8" IWOULD BE CONSIDERED THE "FINISH POINT". |
POSITION PROPORTIONING |
CONTROL OUTPUT THAT UTILIZES TWO RELAYS TO CONTROL AN ELECTRIC OR MOTORIZED ACTUATOR MOTOR |
POTENTIOMETER |
A BALANCING BRIDGE WHICH IS USED TO MEASURE VOLTAGE; ALSO THROUGH THE USE OF A RESISTOR IS USED TO CONTROL A CIRCUIT(S) |
PPM |
STANDS FOR PARTS PER MILLION |
PPR |
SEE "PULSES PER REVOLUTION" |
PRESSURE DROP |
THE DIFFERENCE IN PRESSURE BETWEEN TWO POINTS IN A FLOW SYSTEM. THE PRESSURE DIFFERENCES ARE USUALLY CAUSED BY FRICTIONAL RESISTANCE TO FLUID FLOW IN A CONDUIT, FILTER, OR OTHER FLOW SYSTEM |
PRIMARY LOOP |
THE OUTER LOOP IN A CASCADE SYSTEM |
PROCESS VARIABLE |
ANY CHARACTERISTIC OR MEASURABLE ATTRIBUTE WHOSE VALUE CHANGES WITH CHANGES IN PREVAILING CONDITIONS; SOME COMMON VARIABLES ARE TEMPERATURE, LEVEL, PRESSURE, FLOW, HUMIDITY, ECT. |
PROM |
STANDS FOR "PROGRAMMABLE READ ONLY MEMORY". |
PROPORTIONAL BAND |
THE CHANGE IN INPUT THAT IS REQUIRED TO PRODUCE A FULL RANGE CHANGE IN OUTPUT DUE TO PROPORTIONAL CONTROL ACTION |
PROTECTION TUBE |
A TUBE WHICH IS CLOSED AT ONE END IN WHICH A THERMOCOUPLE IS INSERTED INTO IN ORDER TO PROTECT THE THERMOCOUPLE FROM EXCESSIVE HEAT OR ABRASIVE MEDIUM; PROTECTION TUBES COME IN MANY VARIETIES & MATERIALS. SEE PROTECTION TUBE SELECTIONS STARTING ON Pg. |
PSIA |
STANDS FOR POUNDS PER SQUARE INCH ABSOLUTE |
PSID |
STANDS FOR POUNDS PER SQUARE INCH DIFFERENTIAL |
PSIG |
STANDS FOR GAUGE PRESSURE WHICH IS THE AMOUNT OF PRESSURE ABOVE ATMOSPHERIC PRESSURE |
PSIS |
STANDS FOR POUNDS PER SQUARE INCH STANDARD |
PSYCHROMETER |
MEASURES RELATIVE HUMIDITY |
PULSE WIDTH ERROR |
THE DEVIATION IN ELECTRICAL DEGREES OF THE PULSE WIDTH FROM THE IDEAL VALUE OF 180 DEGREES. |
PULSES-PER-REVOLUTION |
THE NUMBER OF PULSE INTERVALS OF AN OUTPUT SIGNAL FOR EACH REVOLUTION OF THE INPUT SHAFT. |
PWB |
STANDS FOR PRINTED WIRE BOARD |
PYROMETER |
TYPICALLY MEASURES HIGH TEMPERATURES UPTO 2,000 DEGREES F. |
PYROMETRY |
SEE "THERMOCOUPLE" OR "RTD" |
|
QUADRATURE |
THE TERM FOR TWO (2) NEARBY IDENTICAL PERIODIC SIGNALS WHEN THE PHASE DISPLACEMENT IS NOMINALLY 90 ELECTRICAL DEGREES. |