Industry Terms Glossary


N.C.

SEE "NORMALLY CLOSED"

N.O.

SEE "NORMALLY OPEN"

NBS

STANDS FOR NATIONAL BUREAU OF STANDARDS

NEC

STANDS FOR NATIONAL ELECTRIC CODES

NEMA

STANDS FOR NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION

NETWORK 8000

A DIRECT DIGITAL CONTROL (DDC) SYSTEM DEVELOPED BY BARBER-COLMAN CO. (SIEBE CO.) THAT PROVIDES COMPLETE HVAC-BUILDING AUTOMATION

NFPA

STANDS FOR THE NATIONAL FIRE PROTECTION ASSOCIATION

NIGHT SETBACK

A CONDITION GENERALLY ASSOCIATED WITH THERMOSTATS, THAT IS WHEN THE SETPOINT OF THE THERMOSTAT IS SET/SHIFTED TO A LOWER TEMPERATURE DURING UNOCCUPIED HOURS, ESPECIALLY DURING THE HEATING SEASON

NIGHT SETUP

GENERALLY ASSOCIATED WITH THERMOSTATS, WHEN THE SETPOINT IS SET/SHIFTED TO A HIGHER TEMPERATURE DURING UNOCCUPIED HOURS, ESPECIALLY DURING THE COOLING SEASON

NIST

STANDS FOR NATIONAL INSTITUTE FOR STANDARDS AND TECHNOLOGY.

NOISE

AN UNWANTED COMPONENT OF A SIGNAL OR VARIABLE

NORMALLY CLOSED

A TERM/CONDITION THAT APPLIES TO A CONTROLLED DEVICE WHICH CLOSES WHEN EITHER A POWER FAILURE OCURRS, OR WHEN CONTROL PRESSURE IS REMOVED

NORMALLY OPEN

A TERM/CONDITION THAT APPLIES TO A CONTROLLED DEVICE THAT IS OPEN WHEN ALL OPERATING FORCE IS LOST, SUCH AS IN A POWER FAILURE

NPT

STANDS FOR NATIONAL PIPE THREAD

O.D.

STANDS FOR OUSIDE DIAMETER

OA

STANDS FOR OUTDOOR AIR

OCCUPIED MODE

A CONTROL MODE THAT IS USED TO HEAT OR COOL BUILDINGS WHILE THEY ARE OCCUPIED

OFFSET

THE AMOUNT OF DIFFERENCE BETWEEN CONTROL POINT AND SETPOINT IN A PROPORTIONAL CONTROL SYSTEM

OFFSET

THE ADJUSTMENT TO THE ACTUAL INPUT TENMPERATURE AND TO THE TEMPERATURE VALUES THAT THE CONTROLLER USES FOR DISPLAY & CONTROL

OHMETER

USED TO MEASURE ELECTRICAL RESISTANCE

ON/OFF CONTROL

SEE "CONTROL, ON/OFF"

OPEN LOOP

A CONTROL SYSTEM WITH NO SENSORY FEEDBACK

OSHA

STANDS FOR OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

OUTPUT

AN ACTION CAUSED IN RESPONSE TO THE DIFFERENCE BETWEEN SETPOINT AND PROCESS VARIABLE

OUTPUT MODULES

GENERALLY PLUG-IN DEVICES SUCH AS RELAYS THAT PROVIDE POWER HANDLING TO ENABLE PROCESS CONTROL; MODULES CAN BE EITHER BINARY (ON/OFF) OR ANALOG (CONTINUOUSLY VARIABLE) FOR CURRENT LOOP CONTROL

OVERSHOOT

THE CONDITION WHEN TEMPERATURE EXCEEDS SETPOINT DUE TO INITIAL POWER-UP OR PROCESS CHANGES

OXIDIZING

AN ATMOSPHERE THAT CONTAINS SIGNIFICANT AMOUNTS OF ACTIVE OXYGEN.

P CONTROL

STANDS FOR "PROPORTIONING" CONTROL

PARAMETER

ANY SPECIFIC CHARACTERISTIC OF A DEVICE/CONTROL

PARITY

ADDITION OF ALL THE BITS IN A WORD IS COMPARED TO THE PARITY BIT (EVEN OR ODD). IF THEY ARE BOTH THE SAME, THE DATA IS ACCEPTED, OTHERWISE IT IS REJECTED.

PB

STANDS FOR PROPORTIONAL BAND

PCB

STANDS FOR PRINTED CIRCUIT BOARD

PD CONTROL

STANDS FOR "PROPORTIONING CONTROL WITH RATE ACTION

PEAK LOAD

THE MAXIMUM ELECTRICAL LOAD OR THERMAL LOAD REACHED DURING A SPECIFIC PERIOD OF TIME

PERCENT AUTHORITY

GENERALLY COMMON WITH THE ADJUSTMENT OF RECEIVER CONTROLLERS WHICH DETERMINES THE EFFECT OF THE RESET SIGNAL OF THE SECONDARY TRANSMITTER AS A PERCENTAGE (%) OF THE SIGNAL OF THE PRIMARY TRANSMITTER

PHENOLIC

A RESIN BASED TYPE OF HARD RUGGED PLASTIC THAT IS USUALLY USED IN INSULATING. PHENOLIC IS THE SAME AS BAKELITE.

PI CONTROL

STANDS FOR "PROPORTIONING CONTROL WITH AUTO-RESET"

PID CONTROL

STANDS FOR "PROPORTIONING CONTROL WITH AUTO-RESET AND RATE"

PLATINUM

THE NOBLE METAL GENERALLY USED IN TYPES R & S THERMOCOUPLES

PNEUMATIC CONTROLS

CONTROLS THAT RUN ON LOW-PRESSURE COMPRESSED AIR

PNEUMATIC FINISH POINT

THE MAXIMUM AMOUNT OF PRESSURE (PSI) THAT WILL COMPLETELY COMPRESS AN ACTUATOR'S SPRING TO COMPLETE ITS STROKE. EXAMPLE: AN ACTUATOR WITH A SPRING RANGE OF 3 TO 8 PSI; "8" IWOULD BE CONSIDERED THE "FINISH POINT".

POSITION PROPORTIONING

CONTROL OUTPUT THAT UTILIZES TWO RELAYS TO CONTROL AN ELECTRIC OR MOTORIZED ACTUATOR MOTOR

POTENTIOMETER

A BALANCING BRIDGE WHICH IS USED TO MEASURE VOLTAGE; ALSO THROUGH THE USE OF A RESISTOR IS USED TO CONTROL A CIRCUIT(S)

PPM

STANDS FOR PARTS PER MILLION

PPR

SEE "PULSES PER REVOLUTION"

PRESSURE DROP

THE DIFFERENCE IN PRESSURE BETWEEN TWO POINTS IN A FLOW SYSTEM. THE PRESSURE DIFFERENCES ARE USUALLY CAUSED BY FRICTIONAL RESISTANCE TO FLUID FLOW IN A CONDUIT, FILTER, OR OTHER FLOW SYSTEM

PRIMARY LOOP

THE OUTER LOOP IN A CASCADE SYSTEM

PROCESS VARIABLE

ANY CHARACTERISTIC OR MEASURABLE ATTRIBUTE WHOSE VALUE CHANGES WITH CHANGES IN PREVAILING CONDITIONS; SOME COMMON VARIABLES ARE TEMPERATURE, LEVEL, PRESSURE, FLOW, HUMIDITY, ECT.

PROM

STANDS FOR "PROGRAMMABLE READ ONLY MEMORY".

PROPORTIONAL BAND

THE CHANGE IN INPUT THAT IS REQUIRED TO PRODUCE A FULL RANGE CHANGE IN OUTPUT DUE TO PROPORTIONAL CONTROL ACTION

PROTECTION TUBE

A TUBE WHICH IS CLOSED AT ONE END IN WHICH A THERMOCOUPLE IS INSERTED INTO IN ORDER TO PROTECT THE THERMOCOUPLE FROM EXCESSIVE HEAT OR ABRASIVE MEDIUM; PROTECTION TUBES COME IN MANY VARIETIES & MATERIALS. SEE  PROTECTION TUBE SELECTIONS STARTING ON Pg.

PSIA

STANDS FOR POUNDS PER SQUARE INCH ABSOLUTE

PSID

STANDS FOR POUNDS PER SQUARE INCH DIFFERENTIAL

PSIG

STANDS FOR GAUGE PRESSURE WHICH IS THE AMOUNT OF PRESSURE ABOVE ATMOSPHERIC PRESSURE

PSIS

STANDS FOR POUNDS PER SQUARE INCH STANDARD

PSYCHROMETER

MEASURES RELATIVE HUMIDITY

PULSE WIDTH ERROR

THE DEVIATION IN ELECTRICAL DEGREES OF THE PULSE WIDTH FROM THE IDEAL VALUE OF 180 DEGREES.

PULSES-PER-REVOLUTION

THE NUMBER OF PULSE INTERVALS OF AN OUTPUT SIGNAL FOR EACH REVOLUTION OF THE INPUT SHAFT.

PWB

STANDS FOR PRINTED WIRE BOARD

PYROMETER

TYPICALLY MEASURES HIGH TEMPERATURES UPTO 2,000 DEGREES F.

PYROMETRY

SEE "THERMOCOUPLE" OR "RTD"

QUADRATURE

THE TERM FOR TWO (2) NEARBY IDENTICAL PERIODIC SIGNALS WHEN THE PHASE DISPLACEMENT IS NOMINALLY 90 ELECTRICAL DEGREES.