JUMPER |
A WIRE THAT IS USED TO EITHER CONNECT OR BYPASS A POERTION OF A CIRCUIT OR PRINTED WIRE BOARD |
|
K |
SEE "KELVIN" |
KELVIN |
KELVIN, WHOSE SYMBOL IS K, IS DEFINED AS THE UNIT OF THERMODYNAMIC TEMPERATURE, PHYSICAL QUANTITY, OR ABSOLUTE TEMPERATURE WHOSE MAGNITUDE IS 1/273.15 OF THE THERMODYNAMIC TEMP. OF ICE POINT. |
KHZ |
STANDS FOR "KILO HERTZ", A MEASURE OF FREQUENCY. |
KILOWATT |
A KILOWATT OR kw IS EQUAL TO 1000 WATTS |
KILOWATT HOUR |
KILOWATT HOUR OR kwh IS EQUAL TO 1000 WATT HOURS |
kva |
STANDS FOR KILOVOLT AMPERES AND IS EQUAL TO 1000 VOLT AMPS |
|
LAG |
THE PART OF THE WELL THAT IS BELOW THE HEX AND ABOVE THE THREADS. ITS PURPOSE IS TO EXTEND THROUGHOUT THE LAGGING OF THE VESSEL. |
LATENT HEAT |
THE AMOUNT OF HEAT THAT IS NEEDED IN ORDER TO CHANGE AN AMOUNT OF WATER AT 212 DEGREES (F) (100C) FROM LIQUID TO VAPOR AT CONSTANT BAROMETRIC PRESSURE |
LCD |
STANDS FOR LIQUID CRYSTAL DISPLAY |
LED |
STANDS FOR LIGHT EMITTING DIODE |
LINEARIZATION |
THE FUNCTION THAT IS USED TO AUTOMATICALLY LINEARIZE A NON-LINEAR SIGNAL EITHER FROM A THERMOCOUPLE OR R.T.D. THROUGH THE USE OF LOOK-UP TABLES |
LINEARIZATION, SQUARE ROOT |
THE FUNCTION THAT'S USED TO LINEARIZE A NON-LINEAR SIGNAL CORRESPONDING TO THE FLOW BEING MEASURED BY TRANSMITTERS |
LOAD |
THE DEMAND FOR INPUT TO A PROCESS |
LOAD LINE OUT |
A START-UP OUTPUT VALUE WHICH IS TO BRING INITIAL OUTPUT CLOSER TO THE ACTUAL STEADY STATE OUTPUT |
LOAD SHEDDING |
TO TURN OFF ELECTRICAL LOADS IN ORDER TO LIMIT PEAK ELECTRICAL DEMAND |
LOOP POWER |
AN INTERNAL 24-VOLT CURRENT LIMITED POWER SUPPLY USED TO POWER 2 OR 4 WIRE TRANSMITTERS ON THE INPUT OF A CONTROLLER |
LOW PASS INPUT FILTER |
A METHOD USED TO BLOCK FAST ACTING SIGNALS SUCH AS NOISE, WHILE ALLOWING SLOW ACTING SIGNALS (ACTUAL PROCESS VARIABLE) TO PASS |
LPG |
STANDS FOR LIQUIFIED PETROLEUM GAS |
LSIC |
STANDS FOR "LARGE SCALE INTEGRATED CIRCUIT" |
LUX METER |
MEASURES ILLUMINANCE |
|
M |
STANDS FOR "MEGA", OR ONE MILLION |
MAGNETIC FEEDBACK TRANSDUCER |
ANY TRANSDUCER WHICH RELIES ON CHANGES IN ITS MAGNETIC FIELD TO SEND ITS OUTPUT. |
MAINS |
THE TERM "MAINS" IN A PNEUMATIC HVAC SYSTEM ARE LINES THAT CARRY AIR AT A CONSTANT SUPPLY PRESSURE WHICH IS GENERALLY 15 TO 25 PSIG |
MAKE-UP AIR |
OUTDOOR AIR THAT IS BROUGHT INTO A BUILDING FOR VENTILATION |
MAKE-UP WATER |
WATER WHICH IS SUPPLIED TO REPLENISH THE WATER THAT IS LOST BY EITHER EVAPORATION OR LEAKS |
MANOMETER |
MEASURES PRESSURES OF VAPORS & GASES |
MANUAL RESET I |
A FEATURE ON A DIGITAL TEMPERATURE CONTROLLER THAT ADJUSTS ITS PROPORTIONING BAND IN RELATIONSHIP TO ITS SET POINT IN AN EFFORT TO ELIMINATE ERRORS. |
MANUAL RESET II |
A SWITCH ON A LIMIT CONTROL, RELAY, OR SAFETY DEVICE THAT MANUALLY RESETS AFTER THE LIMIT HAS BEEN EXCEEDED OR BROKEN. |
MEAN TEMPERATURE |
THE MAXIMUM & MINIMUM TEMPERATURE OF A PROCESS EQUALIBRIUM WHICH IS AVERAGED. |
MEASURING JUNCTION |
THE JUNCTION OF A THERMOCOUPLE THAT IS SUBJECT TO THE TEMPERATURE. ALSO REFERRED TO AS THE "HOT LEG" OF THE THERMOCOUPLE. THERE ARE THREE (3) BASIC TYPES: GROUNDED, UNGROUNDED, AND REMOTE. |
MECHANICAL RELAY |
SEE "RELAY (MECHANICAL)" |
MENU BLOCK |
GROUPS OF PARAMETERS ARRANGED IN THE SOFTWARE OF A CONTROLLER |
METASYS |
A DIRECT DIGITAL CONTROL (DDC) SYSTEM DEVELOPED BY JOHNSON CONTROLS THAT PROVIDES COMPLETE HVAC-BUILDING AUTOMATION |
MICROAMP |
MEASURED AS 1 MILLIONTH OF AN AMPERE |
MICROCONTROLLER |
A LARGE-SCALE INTEGRATED CIRCUIT THAT HAS ALL THE FUNCTIONS OF A COMPUTER INCLUDING MEMORY AND INPUT/OUTPUT SYSTEMS |
MICROFARAD |
MEASURED AS 1 MILLIONTH OF A FARAD |
MICRON |
MEASURED AS I MILLIONTH OF A METER |
MICROVOLT |
MEASURED AS 1 MILLIONTH OF A VOLT |
MILLIAMP |
MEASURED AS 1 THOUSANDTH OF AN AMP; ABBREVIATION FOR MILLIAMP IS: mA |
MILLIVOLT |
MEASURED AS 1 THOUSANDTH OF A VOLT; ABBREVIATION IS: mV |
MIXING BOX |
A BOX OR ENCLOSURE THAT HAS DAMPERS IN THE HOT & COLD AIR STREAM THAT MIXES THE TWO (HOT & COLD), AND DELIVERS THE MIXED AIR INTO A SPACE AT A SPECIFIED TEMPERATURE |
MOP |
STANDS FOR "MOTOR OPERATED POTENTIOMETER" |
MOV |
STANDS FOR "METAL OXIDE VARISTOR", USED TO PREVENT POWER SURGES & POWER SPIKES. |
MS-DOS |
SEE "DISK OPERATING SYSTEM" |
MSDS |
STANDS FOR MATERIAL SAFETY DATA SHEETS |
MTBF |
STANDS FOR "MEAN TIME BETWEEN FAILURE", WHICH IS AN INDICATION OF THE AVERAGE LIFE EXPECTANCY OF A UNIT WHEN OPERATED WITHIN ITS DESIGN LIMITATIONS. |
MULTIDRIVE |
AN APPLICATION WHERE MORE THAN ONE MOTOR IS BEING CONTROLLED BY ONE CONTROLLER. THERE ARE THREE (3) TYPES: PARALLEL, PROGRESSIVE, & CASCADED. |