GAIN

THE RATIO OF THE CHANGE IN OUTPUT TO THE CHANGE IN INPUT THAT CAUSED IT

GALLONS PER MINUTE

SEE "GPM"

GALVONOMETER

DETECTS EXTREMELY SMALL ELECTRICAL CURRENTS

GAUSS

ELECTROMAGNETIC UNIT OF MAGNETIC INDUCTION

GPH

STANDS FOR "GALLONS PER HOUR"

GPM

STANDS FOR "GALLONS PER MINUTE", WHICH QUANTIFIES WATER FLOW

HEAD

A MEASURE OF PRESSURE WHICH IS EXPRESSED IN FEET; TYPICALLY APPLIES TO CENTRIFUGAL PUMPS, AND INDICATES THE COLUMN HEIGHT OF WATER THAT IS BEING LIFTED BY THE PUMP

HEAT PUMP

A UNIT THAT EITHER HEATS OR COOLS A BUILDING BY USING HEAT FROM THE CONDENSER SECTION OR BY USING COOLING FROM THE EVAPORATOR SECTION

HEAT SINK

USUALLY FOUND ON CIRCUIT BOARDS AND PRINTED WIRE BOARDS (PWB's), A HEAT SINK ACTS TO DISIPATE THE HEAT OF COMPONENTS THAT ARE MOUNTED ON THE SOLID STATE BOARDS.

HEAT/COOL CONTROL

THE METHOD OF CONTROL WHEN THE TEMPERATURE OF THE END PRODUCT IS MAINTAINED BY CONTROLLING TWO FINAL ELEMENTS USING TWO OUTPUTS

HERTZ

UNITS WHICH EXPRESS FREQUENCY; ABBREVIATION IS "HZ"

HOT LEG

SEE "MEASURING JUNCTION"

HUMIDISTAT

MEASURES HUMIDITY IN % OF RELATIVE HUMIDITY WHILE SENSING AND CONTROLLING THE MOISTURE CONTENT OF THE AIR

HUNTING

WHEN A CONTROLLER CAUSES A MOTOR OR ACTUATOR DEVICE TO CONTINUOUSLY TRAVEL FROM ONE END OF ITS STROKE TO THE OTHER

HUNTING

THE OSCILLATION OR FLUCTUATION OF THE PROCESS TEMPERATURE BETWEEN SETPOINT & PROCESS VARIABLE

HVAC

STANDS FOR "HEATING, VENTILATING, & AIR CONDITIONING"

HVAC/R

STANDS FOR "HEATING, VENTILATING, AIR CONDITIONING, & REFRIGERATION"

HYDRAULIC ACTUATOR

AN ACTUATOR THAT EITHER OPERATES VALVES OR DAMPERS BY PRODUCING A LINEAR MOTION AS A RESULT OF THE FLUID PRESSURE DEVELOPED FROM A CONTINUOUSLY RUNNING MOTOR PUMPING OIL THROUGH A TRANSDUCER

HYDRONICS

THE CONTROL & USE OF WATER AS A HEAT TRANSFER MEDIUM IN AIR CONDITIONING SYSTEMS AND BOILERS

HYGROSCOPIC

WATER ABSORBING

HYSTERESIS

IN ON/OFF CONTROL, THE TEMPERATURE CHANGE THAT IS NECESSARY TO CHANGE THE OUTPUT FROM FULL ON TO FULL OFF

IC

STANDS FOR INTEGRATED CIRCUIT

IMMERSION SENSOR

A CONTROL WITH AN  EXTENDED ELEMENT (BULB & CAPILLARY) THAT IS USED TO SENSE THE TEMPERATURE OF STEAM, WATER, ECT. IN LIQUID LINES AND TANKS. IMMERSION SENSORS/CONTROLS MOUNT REMOTELY AND ARE ALSO AVAILABLE IN STRAP-ON MOUNTING

IMPEDANCE

OPPOSITION TO THE FLOW OF ELECTRICITY, RESISTIVE + REACTIVE

IN. W.C.

SEE "INCHES OF WATER COLUMN"

INCHES OF WATER COLUMN

A TERM OF MEASUREMENT THAT IS PRIMARILY USED TO MEASURE & CONTROL LOW DIFFERENTIAL PRESSURES. LOW DIFFERENTIAL PRESSURES INCLUDE THOSE OF DUCT STATIC PRESSURE; SPACE STATIC PRESSURE; AND THE VELOCITY PRESSURE OF FLOWING AIR IN DUCTS.

INFILTRATION

AIR LEAKAGE THROUGH THE JOINTS & CRACKS,  AND WINDOWS & DOORS OF A BUILDING OR STRUCTURE DUE TO EITHER THE ADVERSE PRESSURE EFFECTS OF WIND, OR THE DIFFERENCE IN THE INDOOR & OUTDOOR AIR DENSITY

INFRARED

EXCEEDS RED LIGHT FROM 750 NANOMETERS TO 1,000 MICRONS AND IS USED TO DETECT TEMPERATURE & FLAME WITHOUT MAKING PHYSICAL CONTACT. MOSTLY USED IN THE DETECTION OF INFRARED IN FLAME IN BOILERS, BURNERS, OVENS, KILNS, & INCINERATORS.

INLET VANE

RESTRICTS AIR FLOW INTO CENTRIFUGAL FAN HOUSINGS, AND RESTRICTS REFRIGERANT FLOW ON CENTRIFUGAL CHILLERS

INPUT

PROCESS VARIABLE DATA BEING SUPPLIED TO THE DEVICE. FOR EXAMPLE: FOR A PROCESS TEMPERATURE CONTROLLER THE MOST COMMON FORMS OF INPUT ARE THERMOCOUPLE & R.T.D.

INTEGRAL

THE CONTROL ACTION THAT AUTOMATICALLY ELIMINATES OFFSET, OR "DROP", BETWEEN SETPOINT AND ACTUAL PROCESS TEMPERATURE, AND ALSO "RESET"

INTEGRAL CONTROL

A CONTROL ACTION THAT IS SPECIFICALLY DESIGNED TO EITHER REDUCE OR EVEN ELIMINATE OFFSET IN A PROPORTIONAL CONTROL

INTELLIGENT AUTOMATION

ALSO REFERRED TO AS "I/A", IS A PROCESS CONTROL AUTOMATION SYSTEM DEVELOPED BY FOXBORO CO. (SIEBE) THAT PROVIDES COMPUTER-BASED MONITORING, CONTROLLING, & AUTOMATION TO AN INDUSTRIAL PLANTS PROCESS CONTROL LOOP(s)/SYSTEM

INTERPOLATION

A MATHMATICAL PROCESS THAT ESTIMATES A MISSING FUNCTIONAL  VALUE BY TAKING A WEIGHTED AVERAGE OF KNOWN FUNCTIONAL VALUES AT NEIGHBORING POINTS. (THIS IS DONE ELECTRONICALLY IN SOME DEVICES).

INTERVAL TIMER

A TIMER THAT HAS ITS OUTPUT OCCUR DURING THE TIMING STATE

IPCEA

STANDS FOR THE INSULATED POWER CABLE ENGINEERS ASSOCIATION

IR

STANDS FOR INFRA-RED

ISA

STANDS FOR INSTRUMENT SOCIETY OF AMERICA

ISOLATION

THE ELECTRICAL SEPARATION OF THE SENSOR FROM HIGH VOLTAGE CIRCUITRY. ALLOWS FOR APPLICATION OF GROUNDED OR UNGROUNDED SENSING ELEMENT

ISOTHERMAL

MEANS CONSTANT TEMPERATURE.

ITS90

MEANS THE INTERNATIONAL TEMPERATURE SCALE OF 1990 WHICH IS THE PRESENT STANDARD DEFINED BY 17 FIXED POINTS WHICH ARE ASSIGNED STANDARD VALUES. ITS90 SUPERSEDES IPTS68.