E-P SWITCH |
SEE "ELECTRIC-PNEUMATIC SWITCH" |
EA |
STANDS FOR EXHAUST AIR, AND/OR THE UNIT OF MEASURE: "EACH" |
EARTH GROUND |
A SPECIFIC TERMINAL USED TO ENSURE BY MEANS OF SPECIAL CONNECTION, THE GROUNDING OF PART OF A DEVICE/CONTROL |
ECONOMIZER BAND |
THE RANGE OF TEMPERATURES WITHIN WHICH AN AIR HANDLER IS IN ECONOMIZER MODE. |
ECONOMIZER DEADBAND |
THE RANGE OF TEMPERATURES BETWEEN THE HIGH END END OF AN ECONOMIZER BAND AND THE FIRST STAGE OF MECHANICAL COOLING. |
ECONOMIZER MODE |
A CONTROL MODE IN WHICH RELIEF DAMPERS AND OUTSIDE RETURN AIR DAMPERS ARE CONTROLLED BY AIR TEMPERATURE IN ORDER TO PROVIDE THE MOST ECONOMICAL HEATING AND/OR COOLING |
ELECTRIC-PNEUMATIC SWITCH |
AN AIR FLOW SWITCH, ELECTRICALLY OPERATED WITH NORMALLY-OPENED & NORMALLY-CLOSED INPUTS WHICH LEAD TO A COMMON OUTPUT |
ELECTRO MOTIVE FORCE |
SEE "EMF" |
ELECTRONIC CONTROLS |
GENERALLY USE LOW VOLTAGES AND CURRENTS SUCH AS 20 VOLTS OR EVEN LESS. |
ELECTRONIC DEVICES |
SEE "ELECTRONIC CONTROLS" |
EMF |
STANDS FOR ELECTROMOTIVE FORCE, WHICH IS A RISE IN ELECTRICAL ENERGY |
EMI |
STANDS FOR ELECTROMAGNETIC INTERFERENCE |
ENCODER |
AN ELECTRO-MECHANICAL DEVICE THAT TRANSLATES MECHANICAL MOTION OR POSITION INTO ELECTRICAL SIGNALS. |
ENERGY MANAGEMENT |
A TERM DEVELOPED IN THE 1970'S WHICH PROVIDES SEVERAL TECHNIQUES FOR REDUCING ENERGY CONSUMPTION THROUGHOUT A BUILDING(s) WHILE AT THE SAME TIME MAXIMIZING OPERATING EFFICIENCY. |
ENGINEERING UNITS |
TERMS AND ABBREVIATIONS THAT REPRESENT "MEASURED UNITS"; SOME EXAMPLES INCLUDE: (VAC) VOLTS ALTERNATING CURRENT; (KW) KILOWATTS; (GPM) GALLONS PER MINUTE; (F) FAHRENHEIT; ECT., ECT. |
ENTHALPY |
MEASURE OF TOTAL HEAT OF AIR (SENSIBLE + LATENT) THAT IS MEASURED ABOVE AN ARBITRARY DATUM. THE SPECIFIC ENTHALPY OF DRY AIR IS ASSIGNED A VALUE OF ZERO DEG. (F) AND U.S. ATMOSPHERIC PRESSURE (29.92" OF MERCURY), IS MEASURED IN BTU PER LB. OF DRY AIR |
EP SWITCH |
SEE "ELECTRIC-PNEUMATIC SWITCH" |
EPROM |
MAINLY FOUND ON OR ASSOCIATED WITH ELECTRONIC CIRCUITRY/CIRCUIT BOARDS, STANDS FOR "ERASABLE PROGRAMMABLE READ-ONLY MEMORY" |
EUTECTIC TEMPERATURE |
OCCURS WHENEVER A MIXTURE OF ALLOYS OR METALS REACHES ITS LOWEST POSSIBLE MELTING POINT. |
EVAPORATIVE COOLING |
THE ADIABATIC EXCHANGE OF HEAT BETWEEN AIR AND WATER SPRAY OR WETTED SURFACE. THE WET BULB TEMPERATURE OF THE AIR REMAINS CONSTANT, BUT THE DRY BULB IS DECREASED |
EXCEL SYSTEM |
A DIRECT DIGITAL CONTROL (DDC) SYSTEM DEVELOPED BY HONEYWELL THAT PROVIDES COMPLETE HVAC-BUILDING AUTOMATION |
EXHAUST DAMPER |
THIS TYPE OF SPECIFIC DAMPER NORMALLY OPENS AS THE OUTDOOR AIR DAMPER OPENS AND THE RETURN AIR DAMPER CLOSES. EXHAUST DAMPERS ARE USUALLY FOUND ON OR AS PART OF AIR HANDLING UNITS, AND CAN ALSO BE REFERRED TO AS "RELIEF DAMPERS" |
|
FACTORY MUTUAL |
SEE "FM APPROVED" |
FAHRENHEIT |
THE MOST COMMONLY USED TEMPERATURE SCALE WHICH IS MEASURED IN DEGREES AT 32 DEGREES AT ICE POINT AND 212 DEGREES AT THE BOILING POINT OF WATER. |
FALL TIME |
THE TIME INTERVAL BETWEEN THE POINTS AT WHICH THE INSTANTANEOUS VALUE FALLS FROM 90% TO 10% OF THE SPECIFIED UPPER LIMIT. |
FEEDBACK |
THE PROCESS SIGNAL THAT IS USED IN CONTROL AS A MEASURE OF RESPONSE TO CONTROL ACTION; THE PART OF A CLOSED-LOOP SYSTEM WHICH AUTOMATICALLY BRINGS BACK DATA ABOUT THE CONDITION THAT IS UNDER CONTROL |
FEET PER MINUTE |
SEE "FPM" |
FINISH POINT |
SEE "PNEUMATIC FINISH POINT" |
FLASH POINT |
THE TEMPERATURE AT WHICH A FLAMMABLE LIQUID CAN GIVE OFF ENOUGH VAPOR TO IGNITE OR CAUSE EXPLOSION |
FLOATING CONTROL |
WHEN A TWO-POSITION CONTROLLED DEVICE CAN STOP AT ANY POINT IN ITS STROKE AT LOSS OF CONTROL SIGNAL. THE CONTROLLED DEVICE WILL HOLD THIS POSITION UNTIL THE CONTROLLER SENSES ANOTHER SIGNAL TO REPOSITION THE CONTROLLED DEVICE. |
FLOATING CONTROL ACTION |
SEE "FLOATING CONTROL" |
FLOW COEFFICIENT |
SEE "Cv" |
FLUTTER |
VARIATION IN CYCLE WIDTH FROM CYCLE TO ADJACENT CYCLE. |
FM APPROVED |
STANDS FOR "FACTORY MUTUAL RESEARCH CORP." WHICH SETS SAFETY STANDARDS |
FPM |
STANDS FOR "FEET PER MINUTE", WHICH QUANTIFIES THE VELOCITY OF AIR FLOW |
FPM |
STANDS FOR FEET PER MINUTE |
FPS |
STANDS FOR "FEET PER SECOND" |
FREQUENCY-TO-VOLTAGE CONVERTER |
AN ELECTRONIC DEVICE WHICH DIRECTLY CONVERTS A FREQUENCY INPUT TO A VOLTAGE OUTPUT. |
FS |
STANDS FOR FULL SCALE |